PCI Analytics Zero Air Generators for GC and TOC Analyzers
Zero Air Generator produces a continuous flow of high purity Zero Air at selected pressure. The modular pressure swing adsorption (PSA) unit operates with alternating pressure increase and decrease. Untreated air flows under pressure through the reaction towers containing molecular sieve adsorber. Moisture, CO, CO2, THC, and other unwanted components in the air are adsorbed, leaving Zero Air Gas of require purity. During the desorption cycle, the trapped substances adsorbed are released again at low pressure and the adsorber is ready for next cycle. The residual impurity content of Zero Air Gas can be reduced to practically any value required for the user's application. Zero Air Generators are suitable for use in laboratories and industrial environments.
Zero Air Generator for TOC Analyzer produces a continuous flow of high purity Zero Air at selected pressure. The compressor takes the air from the atmosphere,the hot air is then passed through copper cooling coil. The cool air is then passed through furnace where hydrocarbons are cracked at high temperature (temp. range = 400° to 500° C) in presence of catalyst. The furnace at higher temperature breaks the hydrocarbon into CO2 and H,sub>2O.
Water is drained away through a 5 micron and a 0.01 micron filter. The modular pressure swing adsorption unit operates with alternating pressure increase and decrease Untreated air flows under pressure through the reaction towers containing molecular sieve adsorber. Moisture, CO, CO2, THC, and other unwanted components in the air are adsorbed, leaving Zero Air Gas of required purity. During the desorption cycle, the trapped substances adsorbed are released again at low pressure and the adsorber is ready for the next cycle.
| Technical Data | ||
|---|---|---|
| Specifications | ZAG-02 (for 2-5 GC's) | ZAG-03 (for TOC Analyzer) |
| Moisture | <2 ppm | <0.5 ppm |
| Total Hydrocarbon | <0.5 ppm | <0.2 ppm |
| CO & CO2 | <2 ppm | <0.2 ppm |
| Purity | GC/UHP Grade | TOC/XL Grade |
| Micro Particulates | <0.01 microns | <0.01 microns |
| Capacity of ZAG | 4 LPM at 5 kg/cm2 | 1 LPM at 5 kg/cm2 |
| Method of Purification | Pressure Swing Adsorption (PSA) | Pressure Swing Adsorption (PSA) |
| Start-up Time | 5 minutes | 30 minutes |
| Electrical Requirements | 230 VAC, 50 Hz, 1 ph, 4 Amp | 230 VAC, 50 Hz, 1 ph, 4 Amp |
| Size of ZAG without compressor (in mm) | 582H x 293W x 522D | 735H x 382W x 556D |
| Net weight of ZAG without compressor | 35 kg. | 40 kg. |
| Part No. | Description | UOM | est wt. |
Quantity In Stock |
Price | Quantity to order |
|---|---|---|---|---|---|---|
| ZAG02 | ZAG-02 ZERO AIR GENERATOR WITH OIL FREE AIR COMPRESSOR; OIL FREE AIR COMPRESSOR PURE AIR PURIFIER AND AUTOMATIC AIR DRYER. CAPACITY 4000ml/min at 4kg/cm2 | EA | 0 | 0(#) | $2623.20 | |
| ZAG02FITTINGS | ZAG-02 FITTINGS KIT | KT | 0 | 0(#) | $180.00 | |
| ZAG03 | ZAG-03 ZERO AIR GEN-TOC ZERO AIR GENERATOR FOR TOC ANALYZER MODEL ZAG-03: OIL FREE AIR COMPRESSOR; PURE AIR PURIFIER HIGH EFFICIENCY MICRON FILTER; HC REMOVAL HIGH TEMPERATURE FURNACE. CAPACITY: 500ML/MIN AT 4KG/CM2 | EA | 0 | 0(#) | $4800.00 | |
| ZAG03FITTINGS | ZAG-03 FITTINGS KIT | KT | 0 | 0(#) | $180.00 | |
| (#) Standard lead-time for out-of-stock items is approximately two weeks. | ||||||
Ordering information.
International (non-US) prices available through your
local dealer.
|
||||||
![]() Yttria coated filament at start |
![]() Yttria coated filament after 16,000 cycles |
New Pumps Added to the List of LOW COST S.I.S. Rotary Vane
Vacuum Pumps - Save 35 - 50% off the price of comparable vacuum pumps.
Adixen (Alcatel) ACP Series Compact Dry Roughing Pumps - a frictionless pumping module, optimized for operation without internal lubricant.
- Direct Replacement for the Shimadzu QP5000 Filament.
PCI Analytics Products - product solutions for all Analytical Instrumentation
SilTite FingerTite, the next generation GC capillary ferrule system without the use of any tools.
(25% discount until Oct 31)
Direct Replacement for the Heated Capillary in the Thermo-Fisher Scientific TSQ & LCQ Mass Spectrometers now available
- Ideal for use in analytical instrumentation
- Will improve your laboratory workflow and reporting confidence in many ways
DigiVac Bench Top Vacuum Gauges
- Vacuum instrumentation with everything you need to go to work
Imtakt HPLC Columns
-offer a wide variety of unique stationary phases in their HPLC
columns
Programmable syringe pumps for controlled flow. Model NE-300 priced at only $275.00
NEW: Wiley 9th Edition - 660,000-850,000
spectra (a 65% increase).
NEW: Agilent 5973/75 Replacement Source
Heater and Temperature Sensor
NEW: SIS Direct Replacement
Filament for the Amatek/Dycor RGA Leak Detectors and Quadrupoles
(p/n 95381VE), which tests have shown increase service life.
NEW: SIS
Replacement Filter Elements For Edwards Oil Mist Eliminators -
Save up to 25% off the price of comparable Edwards replacement
elements.
Identify mass spectra via library
search with the fully-evaluated, most widely used mass spectral
reference library, compiled by the National Institute of Standards
and Technology (NIST).
View and capture images or video at
20x/400x power on a PC computer via attached USB cable.