D55
Micro Needle Valves
Scientific Instrument Services, Inc.
TM
FAX: 908-806-6631
www.sisweb.com/catalog/08/D55
Stem
Temp.
Recommended
Pressure
Flow
Valve
Part
Configuration
Length
Connection
Rating
for Vacuum
Rating
Rate
Code
No.
`L' Single Outlet
50 mm
1/16" x 1/16"
300°C
Yes
700psi
0-2000mL/min
MCV
`L' Single Outlet
100mm
1/16" x 1/16"
300°C
Yes
700 psi
0-2000mL/min
MCV
`T' Dual Outlet
50 mm
1/16"x1/16"x1/16"
300°C
Yes
500psi
0-2000mL/min
MCVT
Features
-
For precision metering and on-off control
-
Valves designed specifically for chromatographic
applications.
-
Used at elevated temperatures from high vacuum
to medium pressure.
-
Minimal dead volume flow paths.
-
All installation components are supplied with the valves.
-
High temperature metering valves (300°C)
-
L or T configuration
-
Locknut for attachment to a mounting plate
-
Metering handle must be external to the oven
Stainless Steel Micro Control Valves (MCV)- Manual operation
T
he range of Micro Needle Valves has been designed primarily for fine control of critical gas or liquid flows at elevated
temperatures over a wide range of pressures from high vacuum to medium pressure. They are ideally suited to
chromatography and GC/MS applications.
-
Back pressure regulator
-
Low temperature to 100°C
-
Locknut for attachment to a mounting plate
Brass Micro Control Valves (BMCV) - Manual operation
Stem
Temp.
Recommended
Pressure
Flow
Valve
Part
Configuration
Length
Connection
Rating
for Vacuum
Rating
Rate
Code
No.
Single Outlet
n/a
1/16"
100°C
No
500psi
0-2000mL/min
BMCV-1
Dual Outlet
n/a
1/16"
100°C
No
500psi
0-2000mL/min
BMCV-A
Stainless Steel Manual On/Off Valve (SMOV) - Manual Operation
-
On/off gas regulator
-
Low temperature 100°C
On-Off Valves (Pneumatic Operation)
Stainless Steel Manual On/Off Valve Pneumatic (MOVP) - Pneumatic Operation
-
Pneumatic control On/Off valve
-
Gas regulator for cold traps
-
High temperature 300°C
-
Locknut for attachment to a mounting plate
-
Pneumatic head (black) must be external to oven
On-Off Valves (Manual Operation)
Metering Valves (Manual Operation)
Stem
Temp.
Recommended
Pressure
Flow
Valve
Part
Configuration
Length
Connection
Rating
for Vacuum
Rating
Rate
Code
No.
Single Outlet
n/a
1/16"
100°C
No
400atm
n/a
SMOV
Stem
Temp.
Recommended
Pressure
Flow
Valve
Part
Configuration
Length
Connection
Rating
for Vacuum
Rating
Rate
Code
No.
`L' Single Outlet
50 mm
1/16" x 1/16"
300°C
Yes
500psi
n/a
MOVP
`T' Dual Outlet
50 mm
1/16"x1/16"x1/16"
300°C
Yes
500psi
n/a
MOVPT
`T' Dual Outlet
100 mm
1/16"x1/16"x1/16"
300°C
Yes
500psi
n/a
MOVPT(L)
tip...