D5
SGE Capillary Columns
Scientific Instrument Services, Inc.
TM
FAX: 908-806-6631
www.sisweb.com/catalog/08/D5
I.D.
Length
Film
Part
(mm)
(meter)
Thickness (µm)
Number
0.10
10
0.10
0.15
10
1.20
12
0.25
12
0.40
25
0.25
25
0.40
30
0.15
50
0.25
0.18
40
0.18
0.22
12
0.25
25
0.25
25
1.00
30
0.25
50
0.25
50
1.00
0.25
15
0.25
15
1.00
30
0.25
30
0.50
30
1.00
60
0.25
60
1.00
0.32
6
1.00
12
0.25
12
0.50
12
1.00
15
0.25
15
1.00
I.D.
Length
Film
Part
(mm)
(meter)
Thickness (µm)
Number
0.32
25
0.25
25
0.50
25
1.00
25
3.00
30
0.25
30
0.50
30
1.00
50
0.25
50
0.50
50
1.00
60
0.25
60
1.00
0.53
12
0.25
12
1.00
12
3.00
15
0.50
15
1.00
15
1.50
15
3.00
25
0.25
25
1.00
25
3.00
30
0.50
30
1.00
30
1.50
30
3.00
50
1.00
60
1.00
I.D.
Length
Film
Temperature
Part
(mm)
(meter)
Thickness (µm)
Limits (°C)
Number
0.25
30
0.25
30 to 280/300
30
1.00
30 to 280/300
60
0.25
30 to 280/300
0.32
30
0.25
30 to 280/300
30
0.50
30 to 280/300
60
0.25
30 to 280/300
60
0.50
30 to 280/300
0.53
30
0.50
30 to 280/300
30
1.00
30 to 280/300
The world's highest temperature wax capillary col-
umn at 300°C
-
Low Bleed
-
Robust
-
Inert
A unique, highly inert phase.
forte
TM
S
OL
G
EL
-WAX
I.D.
Length
Film
Temperature
Part
(mm)
(meter)
Thickness (µm)
Limits (°C)
Number
0.32
25
0.40
0 to 360/370
forte
TM
BPX608
35% Phenyl Polysilphenylene-siloxane
Ideal for the analysis of organochlorine herbicides
and pesticides. Suitable replacement for: DB-608,
HP-35, Rtx-35, SPB-608, ZB-35.
forte
TM
BPX5
5% Phenyl Polysilphenylene-siloxane
An MS-Premium, low bleed column with a maximum temperature
up to 370°C. Suitable for trace analysis of pesticides, drugs, hydro-
carbons and phenols. The BPX5 phase has been designed for robust-
ness and is suitable for over 80% of all routine analyses performed by
chromatographers.
CH
3
CH
3
CH
3
CH
3
SI
SI
CH
3
x
y
SI
O
O
Similar Phases
CP-Sil 8CB, DB-5, DB-5.625 XTI-5, DB-5MS, HP-5, HP-5MS, HP5-TA, MDN-
5S, Rtx-5ms, SPB-5, Ultra-2.
Applications
Ultra trace analysis, pesticides/herbicides, hydrocarbons, solvents, phenols,
amines, GC/MS and other specific detector applications.
Temperature Range Isothermal/temperature programmed
0.25µm - 1.0µm film: -40°C to 360°C/370°C
>1.0µm film:
-40°C to 350°C/360°C
tip...
| Page | Parts |
|---|
| ValcoBond VB-50/608 (50%-Phenyl)-methylpolysiloxane GC Capillary Columns | CFSD01010010B, CFSD01010020B, CFSD01010040B, CFSD01018018B, CFSD01018040B, CFSD02010010B, CFSD02010020B, CFSD02010040B, CFSD02018018B, CFSD02018040B, CFSD04018018B, CFSD04018040B, CFSD06032025B |
| ValcoBond VB-35 (35-Phenyl)-methylpolysiloxane GC Capillary Columns | CFSC01010010B, CFSC01010020B, CFSC01010040B, CFSC01018018B, CFSC01018040B, CFSC02010010B, CFSC02010020B, CFSC02010040B, CFSC02018018B, CFSC02018040B, CFSC04018018B, CFSC04018040B, CFSC06032025B |
| SGE SOLGEL-WAX GC Capillary Columns | 054785, 054786, 054787, 054788, 054789, 054791, 054792, 054796, 054797 |
| SGE BPX608 GC Capillary Columns | 054823 |
| SGE BPX5 GC Capillary Columns | 054099, 054100, 054101, 054102, 0541025, 054103, 054104, 054105, 054106, 054107, 054108, 054110, 054112, 054113, 054114, 054116, 054117, 054118, 054119, 054120, 0541205, 054121, 054122, 054123, 054124, 054125, 054126, 0541261, 054127, 054128, 054129, 054130, 054131, 054132, 054133, 054134, 0541344, 0541345, 0541347, 0541348, 054136, 054138, 054139, 054142, 054144, 054145, 054146, 054147, 054148, 054152, 054153, 054154, 054158, 054159, 054160 |